ofWhite Architects

Fatjon Bardho · architect · ofWhite Architects · 2026

Energy efficiency: cutting the bill at the design stage

The short answer: the bill is decided by four things, in this order: orientation, shading, the envelope (insulation and windows) and only then the equipment. The first three are decided on paper. After construction, fixing any one of them costs as much as a new facade.

Orientation: where each room faces

The sun rises in the east, climbs through the south and sets in the west. The house is laid out to match:

  1. SouthThe living room and the rooms used by day. Large windows with an overhang above.
  2. EastBedrooms and the kitchen: sun in the morning, cool in the afternoon.
  3. WestThe low afternoon sun, the hardest to stop. Little glass and vertical louvres.
  4. NorthBathrooms, stairs, storage. Small windows, because here heat is only lost.

The overhang: shade in summer, sun in winter

At noon the summer sun in Tirana stands 72° above the horizon, the winter sun only 25°. An overhang above a south window stops the first and lets in the second. Move the depth:

For a 2.2 m high window facing south, at noon, on 21 June and 21 December. On the east and west an overhang is not enough: the sun is low and vertical louvres are needed.

Insulation: how many centimetres

U shows how much heat passes through the wall: the smaller, the better. Add insulation to a 25 cm brick wall:

Calculated for a 25 cm hollow brick wall with render (U about 1.4 W/m²K) and insulation with a conductivity of 0.036 W/mK, such as polystyrene or stone wool. Your wall may differ.

The windows: the weakest point of the facade

Even the best window loses several times more heat than the wall next to it:

The values are in W/m²K, for the glass. Compare them with a well-insulated wall, about 0.3. The frame needs a thermal break, and the fitting has to seal every gap: a good window badly fitted is a bad window.

The equipment comes last

When the house asks for little, the equipment it needs is smaller and cheaper:

  1. The heat pumpFrom 1 kWh of electricity it delivers 3–4 kWh of heat. It works best with underfloor heating and in an insulated house.
  2. The solar panel for hot waterWith Albania's sun it covers most of the hot water from spring to autumn.
  3. Photovoltaic panelsThey make sense when you use power by day: cooling, a heat pump, working from home.
  4. Ventilation with heat recoveryIn a well-sealed house it brings in fresh air without throwing the heat out.

What the law requires

The basis is law no. 116/2016 “On the energy performance of buildings”:

  1. The minimum requirementsNew buildings and those undergoing full renovation must meet the minimum energy performance requirements approved by DCM no. 537/2020.
  2. The energy performance certificateIt is issued by an energy auditor and shows how much energy the building uses per m² per year. The law provides for it for new buildings and for those sold or rented.

Frequent questions

How many centimetres of insulation do I need?

The first five centimetres do most of the work. From 10 cm up the gain per centimetre falls, and the money is worth more on the windows and the roof.

What matters more: insulation or equipment?

Insulation. A heat pump in an uninsulated house heats the street. First reduce the need, then choose the equipment.

Is the energy certificate mandatory?

Law no. 116/2016 provides for it for new buildings and for those sold or rented. For how it applies to your case, ask your designer or auditor.

The architect's advice

The order of spending: first orientation and the overhang, which cost nothing. Then insulation and windows. The equipment last, once you know how little is needed.

ofWhite Architects

Architecture and interior design studio in Tirana since 2010.

Interactive version on the site →Contact usWhatsApp